PureAirIndex
← Directory

Medify MA-15: CADR & room-size analysis

ENERGY STAR ID 4517791 · Model MA-15 · certified 2025-12-03

smoke71dust79pollen88
EPA room size
110 ft²
reported certification area
1 ACH equivalent
533 ft²
calculated scenario, not a verified claim
Derived operating power
14.9 W
4.77 CADR/W · not independently measured
Energy cost
$14.08/yr
88 kWh/yr at $0.16
Filters
HEPA-Type
Technology
Fan and Filter
Ozone emissions
0 ppb (none detected)
PM2.5 CADR
75

MA-15 CADR: a small-room unit, not an upgrade inferred from its name

The exact MA-15 record reports 71 cfm smoke CADR, 79 cfm dust CADR and 88 cfm pollen CADR, with a reported area of 110 ft². Our calculated coverage at 4.8 equivalent air changes per hour and an 8 ft ceiling is 110.9 ft². The calculation does not replace the reported area.

The MA-14 record reports 75 cfm smoke CADR and 116 ft². The MA-15’s higher model number does not imply more certified clean-air delivery: this MA-15 record reports less smoke CADR. This compares the exact certification records, not build quality, noise or every retail revision. Read the MA-14 evidence analysis.

Does the MA-15 fit a 150 ft² bedroom?

At 150 ft² and an 8 ft ceiling, this record falls short of a 4.8 eACH scenario. It still filters air; it simply delivers fewer equivalent air changes relative to that room volume.

Calculated at the certified smoke output, not a quieter speed
AreaCeilingRequired CADR at 4.8 eACHDelivered eACH
100 ft²8 ft64.0 cfm5.33
100 ft²9 ft72.0 cfm4.73
110 ft²8 ft70.4 cfm4.84
110 ft²9 ft79.2 cfm4.30
150 ft²8 ft96.0 cfm3.55
150 ft²9 ft108.0 cfm3.16
Calculate your room’s smoke CADR requirement

Small wattage is not the same as high efficiency

Medify MA-15 reports 4.77 smoke cfm/W, compared with a median of 5.22 cfm/W across 14 other certification records within ±15% of its smoke CADR. A low-power unit can use little electricity because it delivers less clean air. CADR per watt is the more useful efficiency comparison.

Inspect the 14-record cohort

Electricity: reported annual energy versus constant-power use

The source reports 88 kWh/year, equivalent to $14.08/year at an illustrative $0.16/kWh. This is not a 24/7 operating claim.

A separate scenario at the snapshot’s 14.9 W derived power for 24 hours every day gives 130.5 kWh/year, or $20.88/year at that rate. Derived watts are rounded in the snapshot and are not independently measured. Actual speed, controls and runtime can change consumption; purchase and filters are excluded.

Estimate electricity for your usage

Evidence and limits

Snapshot retrieved 2026-10-20; certified 2025-12-03; exact model MA-15, ID 4517791. PureAirIndex analyzes certification data and has not personally tested this purifier. Noise, quieter-speed CADR, current retail claims, prices and filter costs remain unverified. No sleep-speed or health outcome is inferred.

Coverage and eACH use smoke CADR, room volume and the stated ceiling. Cohorts exclude this ID with inclusive, unrounded ±15% bounds; certification records are not product-family deduplicated. Cohort medians describe this snapshot, not the entire market.

Calculate CADR for your roomMethodologySource recordHow CADR and air changes affect room coverage