ENERGY STAR ID 4437397 · Model MA-14 · certified 2025-06-12 · ENERGY STAR Most Efficient

smoke75dust85pollen90
EPA room size
116 ft²
reported certification area
1 ACH equivalent
563 ft²
calculated scenario, not a verified claim
Derived operating power
14.5 W
5.17 CADR/W · not independently measured
Energy cost
$13.76/yr
86 kWh/yr at $0.16
Filters
HEPA-Type
Technology
Fan and Filter
Ozone emissions
0 ppb (none detected)
PM2.5 CADR
80

Medify MA-14 CADR: what does 75 cfm mean for your room?

The MA-14 record in our ENERGY STAR snapshot reports 75 cfm smoke CADR, 85 cfm dust CADR and 90 cfm pollen CADR. Its reported room area is 116 ft². These figures belong to model number MA-14, ENERGY STAR ID 4437397; they should not be assumed to describe every later retail revision.

Using smoke CADR and an 8 ft ceiling, our calculation gives 117.2 ft² at 4.8 equivalent air changes per hour. That is close to the source’s reported 116 ft², not a substitute for it. The same unit delivers less clean air per hour relative to the room’s volume as the room gets larger.

Calculate the requirement for your room

Room coverage changes with the air-change target

Calculated scenarios using 75 cfm smoke CADR and an 8 ft ceiling. These are not manufacturer coverage claims or measured performance in a home.

2 eACH281.3 ft²
4.8 eACH117.2 ft²
5 eACH112.5 ft²
What the MA-14 delivers in example rooms
Floor areaCeilingCalculated smoke eACH
100 ft²8 ft5.63
150 ft²8 ft3.75
200 ft²8 ft2.81

At 200 ft², this record’s smoke CADR delivers 2.81 eACH rather than 4.8. This is a sizing constraint, not a claim that the unit stops filtering above 116 ft². eACH describes equivalent particle-free air from filtration, not outdoor-air ventilation or a health guarantee.

How efficient is it among similar-airflow records?

We compare it with 16 other records whose smoke CADR falls within ±15% of 75 cfm. The MA-14 reports 5.17 smoke cfm per watt; the peer median is 5.34 cfm/W. Higher cfm/W means more certified smoke clean-air delivery per watt, not necessarily quieter operation or lower lifetime cost.

MA-14 versus its 16-record airflow cohort
MetricMA-14Peer median
Smoke CADR efficiency5.17 cfm/W5.34 cfm/W
Reported annual energy86 kWh87.3 kWh
Inspect the comparison cohort

MA-14 electricity cost: reported energy versus 24/7

The reported 86 kWh/year corresponds to $13.76/year at a hypothetical $0.16/kWh. It is not a claim about continuous use.

A separate constant-power scenario uses 14.5 W, derived from the certified smoke CADR and CADR/W. At that power for 24 hours every day, consumption would be 127.0 kWh/year, or $20.32/year at the same rate. Actual speed settings, controls and use can change consumption; filters and purchase price are excluded.

Estimate electricity costs for your usage

Evidence, formulas and limits

Snapshot captured 2026-10-20. PureAirIndex analyzes certification records; we have not independently tested this MA-14. Noise, lower-speed CADR, current retail price, replacement-filter costs and retail coverage claims remain unverified.

Area = smoke CADR × 60 ÷ (eACH × ceiling height). eACH = smoke CADR × 60 ÷ room volume. Peers exclude this exact ID and use inclusive, unrounded ±15% smoke-CADR bounds; records are not product-family deduplicated. Medians describe this snapshot, not the entire market.

Calculate CADR for your roomMethodologySource recordHow CADR and air changes affect room coverage