PureAirIndex
← Directory

Medify MA-40 V4.0: CADR & room-size analysis

ENERGY STAR ID 4497354 · Model MA-40-V4.0 · certified 2025-08-26

smoke245dust257pollen263
EPA room size
380 ft²
reported certification area
1 ACH equivalent
1838 ft²
calculated scenario, not a verified claim
Derived operating power
44.3 W
5.53 CADR/W · not independently measured
Energy cost
$41.76/yr
261 kWh/yr at $0.16
Filters
HEPA-Type
Technology
Fan and Filter
Ozone emissions
0 ppb (none detected)
PM2.5 CADR
250

MA-40 CADR: the V4.0 record has a specific room-size limit

The exact MA-40-V4.0 record reports 245 cfm smoke CADR, 257 cfm dust CADR and 263 cfm pollen CADR, with a reported area of 380 ft². Our calculated coverage at 4.8 equivalent air changes per hour and an 8 ft ceiling is 382.8 ft². The calculation does not replace the reported area.

The V4.0 suffix matters. This page covers ENERGY STAR ID 4497354, not every purifier sold as “MA-40.” Its 245 cfm smoke rating must not be confused with its higher dust or pollen ratings when using our smoke-CADR sizing method.

Does the MA-40 fit 400 ft² with a taller ceiling?

At 300 ft² and an 8 ft ceiling, this record exceeds a 4.8 eACH requirement. At 400 ft² it falls short, and raising the ceiling further increases the clean-air requirement. A floor-area label alone hides that difference.

Calculated at the certified smoke output, not a quieter speed
AreaCeilingRequired CADR at 4.8 eACHDelivered eACH
300 ft²8 ft192.0 cfm6.13
300 ft²9 ft216.0 cfm5.44
380 ft²8 ft243.2 cfm4.84
380 ft²9 ft273.6 cfm4.30
400 ft²8 ft256.0 cfm4.59
400 ft²9 ft288.0 cfm4.08
Calculate your room’s smoke CADR requirement

How the MA-40’s efficiency compares at similar airflow

Medify MA-40 V4.0 reports 5.53 smoke cfm/W, compared with a median of 6.55 cfm/W across 30 other certification records within ±15% of its smoke CADR. This cohort reduces the distortion of comparing a larger-output unit with much smaller purifiers, but it is not a noise, filter-cost or overall-quality ranking.

Inspect the 30-record cohort

Electricity: reported annual energy versus constant-power use

The source reports 261 kWh/year, equivalent to $41.76/year at an illustrative $0.16/kWh. This is not a 24/7 operating claim.

A separate scenario at the snapshot’s 44.3 W derived power for 24 hours every day gives 388.1 kWh/year, or $62.09/year at that rate. Derived watts are rounded in the snapshot and are not independently measured. Actual speed, controls and runtime can change consumption; purchase and filters are excluded.

Estimate electricity for your usage

Evidence and limits

Snapshot retrieved 2026-10-20; certified 2025-08-26; exact model MA-40-V4.0, ID 4497354. PureAirIndex analyzes certification data and has not personally tested this purifier. Noise, quieter-speed CADR, current retail claims, prices and filter costs remain unverified. No sleep-speed or health outcome is inferred.

Coverage and eACH use smoke CADR, room volume and the stated ceiling. Cohorts exclude this ID with inclusive, unrounded ±15% bounds; certification records are not product-family deduplicated. Cohort medians describe this snapshot, not the entire market.

Calculate CADR for your roomMethodologySource recordHow CADR and air changes affect room coverage